Equipment - Jet gas and water extinguishing instal
Jet gas and water extinguishing installation JFR-250
The working principle is supplying to the fire center of a powerful jet of oxygen-free exhaust gas saturated with fine-sprayed water. 200 kg of the mixture per second is supplied. The action efficiency - ultraspeed and hyperactive cooling of the flame and metallic constructions located in the fire zone. The application area - large fires on oil fields. Especially in the places where metallic constructions are in the flame. No other machine in the world has such cooling effect, so it is impossible to compare it with any other equipment. It has been applied in many oil companies of Russia and Ukraine for over 15 years. This installation successfully extinguished fires in Kuwait in 1992.
Specifications:
- Base chassis – all type.
- Type of turbojet engine – VK-1A
- Quantity of engines – 2
- Power of engine, kg – 1920
- Nominal quantity of revolutions/min (RPM) – 9000
- Quantity of exhausted gas, at n=9000 RPM for two engine kg/s – 38
- Gas temperature in reactive tube (C0) – 645
- Fuel rate per hour, kg/h – 1472
- Fuel tank capacity, I not less – 2500
- Productivity of turbine reactive installation, kg/s not less – 200
- including water l/s – 120
- Slope angle of turbine reactive installation, kg/s not
- up – 60
- down – 15
- Turning angle, degree not less – 180
- Fire-fighting crew, men – 3
|
 |
 |
|
NEWS
|
|
|
 |
CONTACTS
|
The impulse fire installation “Impulse Storm” is destined for extinguishing large fires on gas and oil fields, atomic and thermoelectric power stations without cutting off voltage, and in ammunition depots.
The speed of fire powder supply – 300 kg/sec…
Details>>
|
Jet gas and water extinguishing installation JFR-250.
Speed of gas and water mixture delivery – 200 kg/sec.
Distance of delivery – up to 70 m.
Extinguishing sector - 90.
Possibility of remote control.
Details>>
|
«Multifunctional impulse powder fire extinguisher «IMPULSE STORM»
Clause 7. 3 of the Official Report on certification tests The Siberian Affiliate of the All-Russian Scientific and Research Institute for Fire Defense, Russia, No. 10-02 of July 20, 2002 “The quantity of leakage current according to powder air suspension in combination with powder supply means which excludes contact of the operator with the fire center...
Details>>
|
 |
|